+49 441 94986-0

Information about tests

tensile test aluminium foils

DIN EN 546-2 determination of tensile strength RM, max. load Fmax, elongation at break A 100 oder A50

test method:Mechanical/ technological properties
Norms: DIN EN 546-2 (2007-03)
Needed sample size:small reel (if not available: film stack or hand roll without folds and kinks)

Standardprüfungen

tensile test alumiuim foils A 100 (initial gauge 100 mm)
Tensile test of aluminum foils with a initial gauge (gauge length) of 100 mm with a crosshead speed of 10 mm / min (10% / min).


tensile test alumiuim foils A 50 (initial gauge 50 mm)
Tensile test of aluminum foils with a initial gauge (gauge length) of 50 mm with a crosshead speed of 5 mm / min (10% / min).




back to overview Mechanical/ technological properties

Search examinations


Your contact person

Matthias Böhne +49 441 94986-11
matthias.boehne@innoform.de