+49 441 94986-0

Information about tests

Water Vapour Transmission Rate (WVTR) bottles, packages, moulded parts, tubes, etc. (only suitable for barrier materials, see also "i")

The measurement is carried out by usage of the the water vapor specific hydrolysis- method, which allows to detect even the lowest permeabilities precisely and reproducibly. Besides the offered standard parameters it is also possible to measure under various different temperature and humidity conditions. Attention: This method is only suitable for packs with a good water vapour barrier. Materials with high permeation coefficients, e.g. PA, thermoplastic starch, PLA cannot be measured due to excessive permeation.

test method:permeation
Norms: DIN EN ISO 12572 (2017-05)
DIN EN ISO 15106-3 (2005-05)
Needed sample size:min 2 units

Standardprüfungen

WVTR package standard 23°C/ 85% rel.humidity
Standard test program "Europe" to determine the water vapour permeation of packages. If you need other test conditions, please let us know.


WVTR package standard 38°C/ 90% rel.humidity
Special test program "tropical climate/ asia/ USA" for determination of the water vapour permeation of packages. If you need other test conditions, please let us know.