+49 441 94986-0

Information about tests

Residual solvents determination

DIN EN 13628-2 (industrial method), Headspace gas chromatography FID, multi-method, the test can be used to monitor SML limits values and technical specifications. listing of solvents: acetone, acetic acid, ethyl ester, isopropyl acetate, methyl ethyl ketone (= 2-butanone), methanol, benzen, 2-propanol, ethanol, acetic acid, propyl ester, 2-methyl-4-pentanone, toluene, 1-propanol, hexanal, isobutanol, propylene glycol monomethyl ether (Dowanol PM), 1-butanol, 1,2-propyleneglycol monoethyl ether, 2-propanol, 1-methoxy-, 2-acetate, ethyleneglycol monoethyl ether, 2-ethoxyethylacetat , 1,3-butyleneglycol monomethyl ether

test method:specific migration
Norms: DIN EN 13628-2 (2003-01)
Hausverfahren (externer Anbieter)
Needed sample size:Small reel (if not available: film stack or original sample in gastight packaging). The measurement of foil cuts or manually rolled samples can lead to reduced findings.

Standardprüfungen

SML Konformitätsprüfung
The test is used to monitor SML limits values


Technische Spezifikation
The test serves to verify technical specifications




back to overview specific migration